ACCROPODE™ - Robustness |
|
 |
 |
Proven structural robustness During the development stage, finite-element methods and full-scale drop tests were implemented to check the sturdiness of the unit using ordinary mass concrete.
Concrete strength specifications
| |
Min.compressive strength Fc at 28 days |
Min. tensile strength Ft at 28days |
| Unit volume £ 16.0 m3 |
30 MPa |
3.0 MPa |
| Unit volume > 16.0 m3 |
35 MPa |
3.5 MPa |

Drop tests conducted at development stage
|
|
|